Baumer N 143 Manuale Utente Pagina 28

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 30
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 27
N 143
28 www.baumer.com
6. Error messages
Error messages are visualized by a flashing upper display, alternating between error code and the presently ac-
tive value (normally the target).
MAX limit of the SPA hurt by manual positioning operation.
Troubleshooting: Get SPA back to permitted positioning range.
MIN limit of the SPA hurt by manual positioning operation.
Troubleshooting: Get SPA back to permitted positioning range.
SPA does not attain the target window.
Troubleshooting: Extend tolerance window. Switch to crawling speed at an earlier point.
The target transmitted is outside the MAX limit.
Note: Consider loop operations.
Troubleshooting: Transmit new permissible position value.
The target transmitted is outside the MIN limit.
Note: Consider loop operations.
Troublehsooting: Transmit new permissible position value.