User Manual DENEX MICRO 7/24 Baumer Electric AG
Version 2013-02, V1.6 www.baumer.com Frauenfeld, Switzerland
4.3 Standard Mounting with Beam Stopper
The laser does not hit anything except the beam stopper when no copies are present.
Normal back-edges will not be counted with this mounting. The beam stopper is a black
plate or dark surface no closer than 300 mm to the bottom of the sensor. See figure 4.3.1.
Figure 4.3.1 Standard mounting with beam stopper.